Lumewave Master Fat Removal Machine
BG-1368


Lumewave Master Fat Removal Machine
Theory
Microwave radiofrequency technology uses non-contact treatment to transmit high-frequency wave energy to the fat layer without damaging the skin and muscles. The microwave radiofrequency field generated within the coverage area of the treatment head can selectively heat the large area of adipose tissue uniformly to a temperature a number of degrees higher than the body temperature, generally 45℃ to 49℃, inducing the natural death of fat cells and prompting them to be discharged from the body.
Bio-thermal effect is: when the human body tissues are irradiated by microwaves, the body's polarized molecules, such as water molecules, under the action of microwave high-speed flip, friction so that the temperature of the tissues gradually rise, so it will make the human body tissues to produce a bio-thermal effect, and to obtain the medical effect, and destruction of hyperplasia tissues. The instrument acts on the human body to a depth of 3cm-5cm, on the local use of a certain period of time, the depth of the human body at 5cm can rise to 40 ℃, resulting in a strong penetration of the thermal effect, and high efficiency. Heat can penetrate through the fat layer to the muscle layer, heat vasodilatation caused by increased blood flow, increase capillary pressure, increase the permeability of cell membranes and speed up the metabolism, so that the muscle relaxation, eliminating spasms and relief of muscle spasm, to achieve the purpose of soothing and anti-inflammatory and other purposes, warming requirements are not stringent, characterized by the need to undress.
Parts Introduction
Installation
Treatment Areas and Treatment Time
Once a week for a course of 4 treatments. Each treatment is about 15-20minutes. The time of irradiation of the same part of the body should not exceed 20min.
Treatment times depend on the required depth and area of treatment. Shorter times should be used for areas of small tissue volume. Longer times should be used for larger tissue volume.
Parameters
Power | 450W | |
Frequency | 27.13MHz | |
Acceptable loads | 10 Ω to 1000 Ω | |
Mode | Continuous/Pulse | |
Screen | 10.4inch touch screen | |
Voltage | 220V/110V | |
N. W./G. W. | 37KGS/62KGS | |
Dimensions | 115cm*62cm*48cm | |
Operation Conditions | Ambient temperature | +10 °C to +30 °C (+50 °F to +86 °F) |
Relative humidity | 30 % to 75 % | |
Atmospheric pressure | 700 hPa to 1060 hPa | |
Transport and Storage Condictions | Ambient temperature | -10 °C to +55 °C (+ 14 °F to + 131 °F) |
Relative humidity | 10 % to 85 % | |
Atmospheric pressure | 650 hPa to 1100 hPa | |
Position | vertical | |
Time of storage | max. 1 year | |
Additional conditions | transport only in original containers |
Operation
Advantages